ATL Error Code
This error code indicates over-temperature protection.
E1 & F0 Error Codes
These error codes indicate a communication failure between the indoor and outdoor units.
E2 Error Code
This error code indicates a T1 indoor unit sensor failure.
E3 Error Code
This error code indicates a T2 indoor unit sensor failure.
E4 Error Code
This error code indicates a R454b sensor failure.
E6 Error Code
This error code indicates a refrigerant leakage fault.
E7 Error Code
This error code indicates an indoor control board chip failure.
E8 Error Code
This error code indicates indoor fan protection.
E9 Error Code
This error code indicates a smart controller communication error.
F4 Error Code
This error code indicates a T4 outdoor ambient temperature sensor failure.
F5 Error Code
This error code indicates a T5 exhaust temperature sensor failure.
F6 Error Code
This error code indicates a T3 condenser temperature sensor failure.
F7 Error Code
This error code indicates a T7 temperature sensor failure.
F8 & HE Error Codes
These error codes indicate a T7 temperature sensor error in detecting condensation risks.
F9 Error Code
This error code indicates AC undervoltage and overvoltage protection.
FA & FB Error Codes
These error codes indicate the chip of the outdoor unit main board is faulty.
FC Error Code
This error code indicates an IPM module temperature fault.
FD Error Code
This error code indicates HLP pressure sensor failure.
FE & H8 Error Codes
These error codes indicate a T3 or T5 sensor disconnect error.
FF Error Code
This error code indicates a high-pressure switch disconnection.
H0 Error Code
This error code indicates a communication failure between the main control chip and IPM chip.
H2 & P1 Error Codes
These error codes indicate high-pressure switch protection.
H3 & PD Error Codes
These error codes indicate high pressure abnormal failure protection in Heating mode.
H5 & P2 Error Codes
These error codes indicate low pressure abnormal failure protection.
H6 & P4 Error Codes
These error codes indicate an exhaust temperature too high protection.
L0 & L1 Error Codes
These error codes indicate DC cable bus low or high voltage protection.
LA, LB, LC, LD, LE, & LF Codes
These codes are not error codes.
P3 Error Code
This error code indicates overcurrent protection of the primary or secondary side.
P5 Error Code
This error code indicates an outdoor coil temperature over-high protection in Cooling mode.
P6 Error Code
This error code indicates IPM module protection.
P7 Error Code
These error code indicates T2 freeze protection.
P8 & H4 Error Codes
These error codes indicate an IPM high temperature protection.
P9 Error Code
This error code indicates a DC fan malfunction.
PC & H7 Error Codes
These error codes indicate a wet operation malfunction.