Error Code Table for Diamante & Quantum Wall-Mounted SystemsUpdated an hour ago

This article provides an error code table for Diamante and Quantum wall-mounted systems. 

This article is for the following systems: 

CodeReasonRemark
bcPM2.5 sensor error 
(indoor unit; optional feature)
Use the remote control to check the error code
bdFresh air motor errorFresh air fan motor, fan blade, indoor unit PCB
bECO2 sensor error
(indoor unit; optional feature)
/
bfTVOC sensor error
(indoor unit; optional feature)
Use the remote control to check the error code 
bj
Humidity sensor error 
(indoor unit)
Use the remote control to check the error code
CL
Filter cleaning reminderClean the air filter
d4
Drain pan full protection
/
d5
Access control signal protection/
E0
Indoor and outdoor units communication errorIs the wiring connection between the units correct?
E1
Indoor unit room temperature sensor errorIndoor unit sensor and PCB
E2
Indoor unit coil temperature sensor errorIndoor unit sensor and PCB
E3
Outdoor unit coil temperature sensor errorOutdoor unit sensor and PCB
E4
System abnormality / 
refrigerant shortage
Gas leakage / 2-way or 3-way valve blocked / etc.
E5
Model configuration mismatch
(production line testing only)
/
E6
Indoor unit DC fan faultFan blade, fan motor, and indoor unit PCB
E7
Outdoor unit ambient temperature sensor errorOutdoor unit sensor and PCB
E8
Outdoor unit discharge temperature sensor errorOutdoor unit sensor and PCB
E9
Outdoor unit IPM / compressor drive faultOutdoor unit PCB, compressor, etc.
EA
Outdoor unit current sensor errorIs the outdoor unit PCB broken?
EbCommunication error between indoor main PCB and display boardDisplay board and main PCB
EC
Outdoor unit module communication error/
EE
Outdoor unit EEPROM error1. Is the outdoor unit PCB broken?
2. Try to re-power the unit
EF
Outdoor unit DC fan motor errorFan motor and outdoor unit PCB
EH
Outdoor unit suction temperature sensor error/
Ej
Outdoor unit mid-coil temperature sensor error/
En
Outdoor unit gas pipe temperature sensor error/
EPOutdoor unit compressor top temperature sensor error
/
EUOutdoor unit voltage detection circuit abnormalityOutdoor unit PCB
EyOutdoor unit liquid pipe temperature sensor error/
F0
Indoor unit infrared sensor errorUse the remote control to check the error code
F1
Indoor unit power detection module errorUse the remote control to check the error code
F2Outdoor unit discharge temperature sensor error protectionCheck the troubleshooting for details
F3Outdoor unit coil temperature sensor error protectionCheck the troubleshooting for details
F4
Abnormal refrigerant flow protectionCheck the troubleshooting for details
F5
Outdoor unit PFC protectionCheck the troubleshooting for details
F6
Compressor phase loss / Phase reversal protectionCheck the troubleshooting for details
F7
Outdoor unit IPM abnormal temperature protectionCheck the troubleshooting for details
F8
Outdoor unit 4-way valve reversing abnormalityCheck the troubleshooting for details
F9
Outdoor unit IPM temperature sensor errorOutdoor unit PCB
FA
Outdoor unit compressor phase current detection circuit failureOutdoor unit PCB
Fb
Cooling / Heating overload frequency limitUse the remote control to check the error code
FC
Frequency reduction due to high power consumptionUse the remote control to check the error code
Fd
Refrigerant leak sensor communication errorCheck the troubleshooting for details
FEOutdoor unit IPM / compressor phase overcurrent protectionUse the remote control to check the error code
FF
Frequency reduction due to high IPM temperatureUse the remote control to check the error code
FH
Frequency reduction due to compressor drive limitUse the remote control to check the error code
Fj
Frequency reduction due to high discharge temperatureUse the remote control to check the error code
Fn
Frequency reduction due to high AC input currentUse the remote control to check the error code
FPFrequency reduction to prevent condensationUse the remote control to check the error code
FU
Frequency reduction to prevent coil freezingUse the remote control to check the error code
Fy
Refrigerant deficiency protectionCheck the troubleshooting for details
H1
Outdoor unit high-pressure switch error/
H2
Outdoor unit low-pressure switch error/
Hd
Refrigerant leak protection/
P0Outdoor unit IPM protectionOutdoor unit PCB
P1
Overvoltage / undervoltage protection1. Is the outdoor unit PCB broken?
2. Is the power supply abnormal?
P2
Overcurrent protection1. Is the outdoor unit PCB broken?
2. Is the power supply abnormal?
P4
Outdoor unit high discharge temperature protectionCheck the troubleshooting for details
P5
Cooling / Dry mode overcooling protectionCheck the troubleshooting for details
P6
Cooling mode overheat protectionCheck the troubleshooting for details
P7Heating mode overheat protectionCheck the troubleshooting for details
P8
Outdoor ambient high / low temperature protectionCheck the troubleshooting for details
P9
Outdoor unit compressor drive overload protectionCheck the troubleshooting for details
PA
Mode conflict / indoor unit upper airflow module communication errorCheck the troubleshooting for details