F4 Error CodeUpdated 8 days ago
Introduction
The "F4" error code indicates the system is undergoing cooling system gas flow abnormal protection. This article is for the following systems:
- Diamante Essenza High-Wall (WYT-17)
- Diamante Pro High-Wall (WYT-20)
- Quantum Fresh High-Wall (WYT-FA)
- Quantum Hyperformance High-Wall (WYT-25)
- Quantum Ultra Ceiling Cassette (CYT-24)
- Quantum Ultra Ducted Ceiling Concealed (RYT-24)
- Quantum Ultra Floor-Ceiling Flex (UYT-24)
- Quantum Ultra High-Wall (WYT-24)
When the compressor starts up, the system will check the variation of the indoor unit coil temperature. If the installer did not open the 2-way or 3-way valve on the outdoor unit, the gas can't flow into the cooling system. The system will undergo cooling system gas flow abnormal protection and display the error code.
Troubleshooting Diagram