Error Code Table for CYB-20, CYK-24, FYB-24, RYB-20, and UYB-20 SystemsUpdated a few seconds ago

This article provides an error code table for Diamante and Quantum light-commercial systems. 

This article is for the following systems: 

CodeReason
dFDefrost mode (Not an error code)
EC07Outdoor unit fan speed abnormal
EC51Outdoor unit EEPROM parameter error
EC52Outdoor unit coil temperature sensor (T3) error
EC53Outdoor unit ambient temperature sensor (T4) error
EC54Compressor discharge temperature sensor (TP) error
EC55IGBT temperature sensor (TH) open-circuit or short-circuit error
EC71Outdoor unit fan overcurrent fault
EC72Outdoor unit fan phase fault
EC73Outdoor unit DC fan zero-speed fault
EC74Outdoor unit fan current sampling offset fault
EC75Outdoor unit fan module protection or hardware overcurrent protection
EH00Indoor unit EEPROM error
EH03Indoor unit abnormal fan speed
EH0AIndoor unit EEPROM parameter error
EH0bCommunication error between the display board and indoor unit PCB
EH0EWater-level alarm error
EH0FIntelligent Eye sensor error
EH12Main or secondary unit error
EH30Indoor unit fan parameter error
EH31Indoor unit fan (1) speed error
EH32Indoor unit fan (2) speed error
EH35Indoor unit fan phase fault
EH36Indoor unit fan current sampling offset fault
EH37Indoor unit fan zero-speed fault
EH38Indoor unit fan stall fault
EH39Indoor unit fan out-of-step fault
EH3AOutdoor unit fan DC bus undervoltage protection
EH3bOutdoor unit fan DC bus overvoltage protection
EH3EIndoor unit fan overcurrent fault
EH3FIndoor unit fan module protection or hardware overcurrent protection
EH60Indoor unit room temperature (T1) error
EH61Indoor unit evaporator coil temperature sensor (T2) error
EHbACommunication error between the indoor unit and fan module
EHb3Communication error between the indoor unit PCB and wired controller
(For KJR-120X/KJR-120M/KJR-120N series wired controller)
EHb5Intelligent Eye sensor communication fault
EHC1Refrigerant leak detected
EHC2Refrigerant sensor reading out of range and leak detected
EHC3Refrigerant sensor reading out of range
EL01Indoor and outdoor units communication error
EL0CInsufficient refrigerant 
EL11Communication error between the main and secondary units
FH07Communication error between the indoor unit and auto-lifting panel
FHCCRefrigerant sensor fault
LC01Compressor frequency limited by outdoor coil temperature (T3)
LC02Compressor frequency limited by discharge temperature (TP)
LC03Compressor frequency limited by abnormal current
LC05Compressor frequency limited by abnormal voltage
LC06Compressor frequency limited by PFC protection
LC30Compressor frequency limited by high pressure
LC31Compressor frequency limited by low pressure
LH00Compressor frequency limited by indoor coil temperature (T2)
LH07Compressor frequency limited by remote control setting
LH30Indoor unit fan current limit protection
LH31Indoor unit fan voltage limit protection
PC00Outdoor unit IPM protection
PC01Outdoor unit voltage protection
PC02Compressor top or IPM temperature protection
PC03High or low pressure protection
PC04Inverter compressor drive error
PC06Compressor discharge temperature (TP) protection
PC08Outdoor unit abnormal current protection
PC0ACondenser high-temperature protection
PC0FPFC module error
PC0LOutdoor unit low ambient temperature protection
PC10Undervoltage protection
PC11Overvoltage protection
PC12DC voltage protection
PC30System overpressure protection
PC31System underpressure protection
PC40Communication error between the outdoor main control chip and compressor drive chip
PC41Input overcurrent protection
PC42Compressor startup error
PC43Phase loss protection (3-phase power supply)
PC44Outdoor unit zero-speed protection
PC45341PWM error
PC46Abnormal compressor speed
PC49Compressor overcurrent protection
PH09Anti-cold air protection in Heating mode
PH0CIndoor unit humidity sensor fault
PH90Evaporator coil high-temperature protection
PH91Evaporator coil low-temperature protection