Perform Routine Maintenance on ECOasis 50 Energy Recovery VentilatorUpdated 2 days ago

Introduction

This article explains how to perform routine maintenance on ECOasis 50 Ductless Wall-Mounted Single-Room Energy Recovery Ventilators

Clean the Ceramic Energy Regenerator & F7 Filter

Loosen the screws on the top of the main unit. 

After unplugging the connecting wires, remove the main unit and inner duct from the wall separately. 

Remove both the F7 filter and ceramic energy regenerator from the inner duct. The ceramic energy regenerator is fragile, it should be carefully removed to avoid damage. 

Clean the ceramic energy regenerator at least four times a year. This part can be rinsed directly with water. After the rinsing is done, place the ceramic energy regenerator in a sunlit location and wait until it fully dries. Even regular technical maintenance may not completely prevent dirt accumulation on the regenerator assemblies. 

Treat the exchanger with regular cleaning to ensure high heat exchange efficiency. Clean the exchanger using a vacuum cleaner at least once a year. 

Replace the filter regularly. The filter is not washable and should be vacuumed when dirty. It's recommended to change the filter each time the alert displays. 

Clean the prefilter at least four times a year. The user can wash or vacuum the prefilter. Allow the prefilter to dry completely, then reinstall it in the air duct. The life duration of the prefilter is about 3 years. 

Contact the distributor or vendor to purchase the replacement filters. 

Clean the Fan

Remove the secured bracket from within the inner duct and take out the fan. 

Once a year, clean the impeller blades by using a soft brush or vacuum cleaner. Do not use water, abrasive detergents, solvents, or sharp objects. 