Introduction
This article explains the Defrost function for QHD070 Whole-House Ducted Dehumidifiers. This product uses a fan-based defrosting method.
Entering Defrost Mode
In Dehumidification mode, when the coil temperature is less than or equal to 30°F (-1°C) and the duration is greater than or equal to 15 minutes, the Defrost mode is activated.
When the Defrost mode activates, the following will occur:
- The compressor turns off.
- The fan runs.
- The defrost indicator flashes.
- The dehumidification indicator turns off .
Exiting Defrost Mode
Defrost mode is exited when the coil temperature is greater than 37°F (3°C) and the duration is greater than 3 minutes.
When the Defrost mode exits, the following will occur:
- The fan continues running.
- The compressor turns on.
- The defrost indicator turns off.
- The dehumidification indicator turns on.