Support Center logo
Support Center logo

All articles

Display the Current Indoor Temperature on Diamante Ultra SystemsUpdated 7 hours ago

Introduction

Learn how to get Diamante Ultra Wall-Mounted (WYT-22) systems to display the current room temperature detected by the indoor unit.  

Note: This article is for a product that is discontinued. 

Steps

  1. Power on the remote controller.
  2. Press the “Fan”, “Mode”, and “Up-Down Swing” buttons together simultaneously for at least 5 seconds. The remote control will display “00” and enter the parameter inquiry function.
  3. Press the temperature setting button to change the value.
  4. Select “01” as the desired parameter. Note: Refer to the General Parameter Code List section for additional information on parameter codes.
  5. Press the “Mode” button while pointing the remote controller towards the indoor unit. The indoor unit will display the corresponding parameter for 30 seconds.
  6. Power off the remote controller to exit the inquiry interface.

General Parameter Code List

Note: Some models might not have these parameters. 

No.
Description
1Indoor room temperature
2Indoor coil temperature
3Outdoor temperature
4Outdoor coil temperature
5Compressor discharge temperature
6Unit running current
7Display error code (if there is no error code, display '---')
11Compressor frequency
12Indoor fan speed
13Outdoor fan speed
14Compressor current
15Expansion valve opening degree
Was this article helpful?
Yes
No