Display the current indoor temperature on Diamante Pro Series systemsUpdated 19 hours ago

Introduction

Learn how to get your wall-mounted WYT-19 Diamante Pro Series system to display the current room temperature detected by the indoor unit.  

Steps

  1. Power On the remote controller.
  2. Press the “Fan”, “Mode”, and “Up-Down Swing” buttons together simultaneously for at least 5 seconds. The remote control will display “00” and enter the parameter inquiry function.
  3. Press the temperature setting button to change the value.
  4. Select “01” as the desired parameter. Note: Refer to the General Parameter Code List section for additional information on parameter codes.
  5. Press the “Mode” button while pointing the remote controller towards the indoor unit. The indoor unit will display the corresponding parameter for 30 seconds.
  6. Power Off the remote controller to exit the inquiry interface.

General Parameter Code List

The following is a general parameter code list: 

Note: Some models might not have these parameters. 

  • 01: Indoor room temperature
  • 02: Indoor coil temperature
  • 03: Outdoor temperature
  • 04: Outdoor coil temperature
  • 05: Compressor discharge temperature
  • 06: Unit running current 
  • 07: Display error code (if there is no error code, display '--')
  • 11: Compressor frequency
  • 12: Indoor fan speed
  • 13: Outdoor fan speed
  • 14: Compressor current
  • 15: Expansion valve opening degree