Wiring the Pioneer CYB Cassette Panel to the Air HandlerUpdated a year ago
CYB Series Ceiling Cassette Panel to Indoor Unit Air Handler Wiring
On the CYB/CB series decorative cassette panel, there are 3 wires that hang off of the panel itself.
- A 5-pin female connector for connecting a wired thermostat (optional)
- A 10-pin main receiver female connector that goes to the main board of the indoor unit
- A 5-pin swing louver female connector that goes to the main board of the indoor unit
The first black head connector is optional and is meant to accept wired thermostats such as our KJR-12B model.
The second and third white head connectors are required for operation and are connected to the indoor unit's main board during installation. There may be a dummy connector pre-attached to the 5-pin area on the main board, you can remove and discard it.