Support Center logo
Support Center logo

All articles

Activate Auto ModeUpdated 2 days ago

Introduction

This article explains how to activate Auto mode for RV rooftop systems

In this mode, the system manages the compressor, heat pump, and feed speeds entirely autonomously. The system accomplishes this by comparing the set temperature with the current internal temperature to determine whether to output heating or cooling. 

In the auto speed setting, the ventilation speed is set according to the difference in temperature between the set point and current ambient temperature. 

Auto fan speed is determined by the difference between the set and room temperature. 

The selected configuration will be retained in the system's memory when it is switched on again next. 

Steps

  1. Press the On/Off button to switch the machine on or off. 
  2. Press the Mode button to cycle through the operating modes, then select Auto mode. 
  3. Use the temperature selection buttons to select the desired set point temperature. 
  4. Press the fan speed buttons to select low, medium, high, or automatic fan speed. 


Was this article helpful?
Yes
No