Cable Wire Specifications for Quantum Ultra High-Wall SystemsUpdated 3 days ago
Introduction
This article provides the cable wire specifications for Quantum Ultra High-Wall (WYT-24) systems.
The power wire sizes assume the largest allowable fuse. 115V systems take a single-pole breaker for the main circuit panel. 
230V systems require a double-pole breaker, tandem-type breakers will not work. 
Consult the nameplate on the system for detailed electrical specifications.
Cable Wire Specifications
| Quantum Ultra High-Wall (WYT-24) | Section Area (AWG) | ||||
| 9K/12K (115V) | 9K/12K (230V) | 18K | 24K | ||
| Power Supply Cable | N (L2) | 12 AWG | 14 AWG | 12 AWG | 12 AWG |
| L (L1) | |||||
![]() | |||||
| Connection Cable for Communication Between Indoor and Outdoor Units | 3 (L) | 16 AWG | 16 AWG | 16 AWG | 16 AWG |
| 2 (N) | |||||
| 1 (S) | |||||
![]() | |||||