Cable Wire Specifications for Quantum Ultra Ducted Ceiling Concealed SystemsUpdated 3 days ago

Introduction

This article provides the cable wire specifications for Quantum Ultra Ducted Ceiling Concealed (RYT-24) systems. 

The power wire sizes assume the largest allowable fuse.

The Quantum Ultra Ducted Ceiling Concealed series, which is a 230V system, requires a double-pole breaker. Tandem-type breakers will not work. 

Consult the nameplate on the system for detailed electrical specifications. 

Cable Wire Specifications

Quantum Ultra Ducted Ceiling Concealed (RYT-24)Section Area (AWG)
9K12K18K
24K
Power Supply CableL214 AWG
14 AWG
12 AWG12 AWG
L1
Connection Cable for Communication Between Indoor and Outdoor Units3 (L)
16 AWG
16 AWG
16 AWG
16 AWG
2 (N)
1 (S)