Error Code Table for QHD070 Whole-House Ducted DehumidifiersUpdated 10 days ago

This article provides an error code table for QHD070 Whole-House Ducted Dehumidifiers

If multiple faults occur simultaneously, the codes will be displayed in order. 

Code
Description
System Response
Suggested Resolution
E0Communication failureAlarm + ShutdownInspect the communication cable and reconnect or replace if necessary
E1Humidity sensor faultAuto-switch to continuous Dehumidification modeConfirm that the temperature and humidity sensors are securely connected. Reconnect or replace if necessary
E2Temperature sensor faultError display onlyConfirm that the temperature sensor is securely connected. Reconnect or replace if necessary
E3Water reservoir full alarmEnter Standby modeCheck for clogged drainage lines or repair/replace the water pump
E4Coil temperature 
sensor fault
Enter Standby mode
Confirm that the coil temperature sensor is securely connected. Reconnect or replace if necessary