PA Error CodeUpdated an hour ago

PA Error Code: Top Flow Unit Communication Failure or Preset Mode Conflict

Causes

  1. If the first indoor unit to turn on operates in Cooling or Dehumidification mode, the other indoor units can operate only in Cooling, Dehumidification, or Air Supply mode. An indoor unit set to any other mode reports a mode conflict fault and does not start. This fault does not affect indoor units that are already running.
  2. If the first indoor unit to turn on operates in Heating mode, the other indoor units can operate only in Heating mode. An indoor unit set to any other mode reports a mode conflict fault and does not start. This fault does not affect indoor units that are already running.

Solution

Set all the indoor units to the same mode. 

Note

Avoid running the units on Auto mode, as it could cause this error.