Matching the Lineset Diameter to Your Pioneer Indoor UnitUpdated 2 hours ago

Introduction

Use this lineset diameter selection guide for Pioneer HVAC mini-split and multi-zone systems. Match your indoor unit to the correct lineset diameter using the tables below.

For single-zone systems, the connection diameter for the indoor and outdoor units will be the same.

For multi-zone equipment, the connection diameter is typically 1/4 to 3/8 inches for the first three valve sets, and 1/4 to 1/2 inches for valve sets 4 and 5.

Wall-Mounted Units

SeriesModel NumberGasLiquid
Diamante Essenza 
High-Wall
(WYT-17)
WYT012ALUI17RL3/8"1/4"
WYT012GLUI17RL3/8"1/4"
WYT018GLUI17RL3/8"1/4"
WYT024GLUI17RL1/2"1/4"
WYT036GLUI17RL5/8"1/4"


SeriesModel NumberGasLiquid
Diamante Essenza
High-Wall
(WYT-20U)
WYT009ALUI20RL3/8"1/4"
WYT009GLUI20RL3/8"1/4"
WYT012ALUI20RL3/8"1/4"
WYT012GLUI20RL3/8"1/4"
WYT018GLUI20RL3/8"1/4"
WYT024GLUI20RL1/2"1/4"
WYT030GLUI20RL5/8"1/4"
WYT036GLUI20RL5/8"1/4"


SeriesModel NumberGasLiquid
Diamante Pro
High-Wall
(WYT-20S)
WYT009ALSI20RL3/8"1/4"
WYT009GLSI20RL3/8"1/4"
WYT012ALSI20RL3/8"1/4"
WYT012GLSI20RL3/8"1/4"
WYT018GLSI20RL3/8"1/4"
WYT024GLSI20RL1/2"1/4"
WYT030GLSI20RL5/8"1/4"
WYT036GLSI20RL5/8"1/4"


SeriesModel NumberGasLiquid
Quantum Ultra
High-Wall
(WYT-24)
WYT009ALSI24RL3/8"1/4"
WYT009GLSI24RL3/8"1/4"
WYT012ALSI24RL3/8"1/4"
WYT012GLSI24RL3/8"1/4"
WYT018GLSI24RL1/2"1/4"
WYT024GLSI24RL5/8"1/4"


SeriesModel NumberGasLiquid
Quantum Hyperformance
High-Wall
(WYT-25)
WYT009GLSI25RH3/8"1/4"
WYT012GLSI25RH3/8"1/4"
WYT018GLSI25RH1/2"1/4"
WYT024GLSI25RH5/8"1/4"


SeriesModel NumberGasLiquid
Quantum Fresh
High-Wall
(WYT-FA)
WYT012GLUI25FV3/8"1/4"


Ceiling Cassette Units

SeriesModel NumberGasLiquid
Quantum Ultra
8-Way Ceiling Cassette
(CYT-24)
CYT009GLSI24RL3/8"1/4"
CYT012GLSI24RL3/8"1/4"
CYT018GLSI24RL1/2"1/4"
CYT024GLSI24RL5/8"1/4"


SeriesModel NumberGasLiquid
Quantum Ultra
4-Way Ceiling Cassette
(CYT-24)
CYB036GMSI20RL3/4"3/8"
CYB048GMSI20RL3/4"3/8"


Ducted Ceiling Concealed Units

SeriesModel NumberGasLiquid
Quantum Ultra
Ducted Ceiling Concealed
(RYT-24)
RYT009GLSI24RL3/8"1/4"
RYT012GLSI24RL3/8"1/4"
RYT018GLSI24RL1/2"1/4"
RYT024GLSI24RL5/8"1/4"


Ducted Central Split Units

SeriesModel NumberGasLiquid
Quantum Ultra
Ducted Central Split
(DYC-18)
DYC024GCSI18RD3/4"3/8"
DYC036GCSI18RD3/4"3/8"
DYC048GCSI18RD7/8"3/8"
DYC060GCSI18RD7/8"3/8"


Floor/Ceiling/Low-Wall Flex Units

SeriesModel NumberGasLiquid
Quantum Ultra
Universal Flex
(UYT-24)
UYT018GLSI24RL1/2"1/4"
UYT024GLSI24RL5/8"1/4"


SeriesModel NumberGasLiquid
Quantum Ultra
Universal Flex
(UYB-20)
UYB036GMSI20RL3/4"3/8"
UYB048GMSI20RL3/4"3/8"


Floor/Low-Wall Mounted Console Units

SeriesModel NumberGasLiquid
Quantum Ultra
Floor-Mounted Console
(FYB-24)
FYB012GMSI24RL3/8"1/2"
FYB018GMSI24RL1/4"1/4"


Multi-Zone Units

SeriesModel NumberGasLiquid
Multiple Size Adapters Provided
Quantum Ultra
Multi-Zone
(YNL-24)
YN020GLSI24M2G
3/8" 
(1/2" for 18,000 BTU adapters and 5/8" for 24,000 BTU adapters)
1/4"
YN030GLSI24M3G
1/4"
YN040GLSI24M4G
1/4"
YN050GLSI24M5G
1/4"
YN060GLSI24M6G
1/4"


One-Way Ceiling Cassette Units

SeriesModel NumberGasLiquid
Quantum Ultra One-Way 
Ceiling Cassette
(CYK-24)
CYK009GMSI24RL3/8"1/4"
CYK012GMSI24RL3/8"1/4"
CYK018GMSI24RL1/2"1/4"