Error Code PC 03 (PC03)Updated a year ago
Error Code PC 03 (PC03) Troubleshooting
High-Pressure or Low-Pressure Protection Diagnosis and Solution
Scope of Models Covered:
Single-Zone Mini Split Systems | Multi-Zone and Light Commercial Mini Split Systems |
YN009AMFI20RPD / WS009AMFI20HLD | YN020GMFI22M2E |
YN009GMFI20RPD / WS009GMFI20HLD | YN030GMFI22M3E |
YN012AMFI20RPD / WS012AMFI20HLD | YN040GMFI22M4E |
YN012GMFI20RPD / WS012GMFI20HLD | YN050GMFI22M5E |
YN018GMFI20RPD / WS018GMFI20HLD | CB009GMFILCFHD / CB012GMFILCFHD / CB018GMFILCFHD / CB024GMFILCFHD |
YN024GMFI20RPD / WS024GMFI20HLD | RB009GMFILDFHD / RB012GMFILDFHD / RB018GMFILDFHD / RB024GMFILDFHD |
YN030GMFI20RPD / WS030GMFI20HLD | FB012GMFILDFHE / UB018GMFILCFHD / UB024GMFILCFHD |
YN036GMFI20RPD / WS036GMFI20HLD | WS009GMFI22HLE / WS012GMFI22HLE / WS018GMFI22HLE / WS024GMFI22HLE |
YN009AMFI22RPE / WS009AMFI22HLE YN012AMFI22RPE / WS012AMFI22HLE | YN009GMFI22RPE / YN012GMFI22RPE / YN018GMFI22RPE / YN024GMFI22RPE |
This code appears when the system detects that internal refrigerant levels are imbalanced. The first things to check are...
- If this is a brand new installation (within few days): Check that the outdoor unit's valves are backed out all the way counter-clockwise. Make sure that the lineset being utilized is at least 10 feet in length, else the system may be factory overcharged.spec. Check to see if there are any major leaks occurring at the connection points of the lineset (use a soapy spray and look for bubbling). Fix any found leaks and recharge to
- If this is a very recent installation (within few weeks): If the unit was working for some time and is now showing this error, a likely culprit is a minor leak allowing refrigerant to leak out over time. Check to see if there are any minor leaks occurring at the 4 separate connection points of the lineset (use a soapy spray and look for bubbling). Fix any found leaks and recharge to spec.
For other instances of the error, some additional troubleshooting can be followed via below steps.