Cable Wire Specifications for Diamante Essenza High-Wall SystemsUpdated 8 hours ago

Introduction

This article provides the cable wire specifications for Diamante Essenza High-Wall (WYT-17) systems

The power wire sizes assume the largest allowable fuse. This series offers 115 voltage and 230 voltage systems. 

The 115V systems take a single-pole breaker for the main circuit panel. 

The 230V systems require a double-pole breaker, tandem-type breakers will not work. 

Consult the nameplate on the system for detailed electrical specifications. 

Cable Wire Specifications

Diamante Essenza High-WallSection Area (AWG)
11.5K/115V11.5K/230V17K
23K
35K
Power Supply CableN (L2)12 AWG
12 AWG
12 AWG12 AWG12 AWG
L (L1)
Connection Cable for Communication Between Indoor and Outdoor Units3 (L)
16 AWG
16 AWG
16 AWG
16 AWG
16 AWG
2 (N)
1 (S)